What Is The Fire Training Tower?

What is the fire training tower?

Chapter VI of fire station building design standard GNJ 1-81 - Requirements for building fire training tower and article 6.0.1 of production standard Annex: training tower shall be set in fire station, and runway with length not less than 35m shall be set in front of it.

The training tower shall meet the following requirements: 1. The training tower shall be set near the end of the training ground to reserve a runway, and a 1.5m sand pit shall be reserved in front of the tower. 2、 The number of floors of training tower shall not be less than four. In cities with more high-rise buildings, the number of floors can be increased appropriately. 3、 There are no less than two windows on each floor on the front of the training tower, and the width between the windows (according to the wall) is 1.0m. 4、 The size of the window of the training tower is 1.2m × 1.8m, the distance between the window and the edge of the tower shall not be less than 0.65M, the width of the windowsill shall be 0.35m, the thickness of the windowsill plate shall be 0.05 (5cm protruding from the tower wall), the height of each windowsill from the ground of the floor shall be 0.8m, the height of the floor shall be 3.5m, and there shall be an internal staircase with a clear width of not less than 0.7m, and the diameter of the handrail tube of the staircase shall not be less than 0.026m. 5、 A platform not less than 1.5m wide shall be set inside each floor of the training tower, and a floor shall be set on the top floor. 6、 The training tower should be equipped with outdoor fire ladders. The fire ladder should be connected to the top of the tower, and should be set up at a height of 3 meters from the ground, and the width should not be less than 50 cm. Training tower Description: 1. It is mainly composed of (1) simulation window, (2) floor partition, (3) rear frame, (4) lookout, command platform frame and main steel structure frame. The front end of the tower body is provided with simulation windows (several layers and windows are customized according to the needs), and floor partitions (steel plates) are set between the upper and lower adjacent simulation windows. 2. A rear frame corresponding to the simulation window is arranged under the rear part of the tower body. 3. The simulation window and the floor partition board as well as the rear frame and the main frame are connected as a whole by bolts. 4. There are safety stairs between floors. 5. The upper part of the tower is equipped with a lookout and command platform. 7、 Generally, the anti-corrosion treatment of training tower is spray paint, and the color is military green. Or camouflage and galvanizing. 8、 The steel structure fire-fighting training tower has complete functions, which can be unloaded, loaded, not limited by the region, terrain and plot. The materials are assembled with accessories, with low cost and high recovery rate. It greatly saves funds for the army and achieves twice the result with half the effort. Welcome to order our fire training tower.


Send Inquiry