What are the requirements of the fire training tower

What are the requirements of the fire training tower

 

What are the requirements of the fire training tower? Let us introduce you:


1. The training tower should be located near the end of the training ground;

2. The number of floors of the training tower should not be less than four. For cities with many high-rise buildings, the number of floors can be increased appropriately;

3. There are no less than two windows on each floor of the training tower, and the width of the wall between the windows is 1.0m;

4. The size of the training tower window is 1.5m×1.8m, the window should not be less than 0.65m from the edge of the tower, the width of the window sill is 0.4m (protruding from the tower wall by 5cm), and the height of each window sill from the ground of the floor is 0.8m. The height is 3.5 meters, and there should be an internal staircase with a clear width of not less than 0.7 meters;

5. A platform not less than 1.5 meters wide should be set on the inner side of each floor of the training tower, and a floor slab should be set on the top floor;

6. The training tower should be equipped with an outdoor fire-fighting ladder. The fire ladder should reach the top of the tower and should be set up 3 meters above the ground. The width of the fire training tower should not be less than 50 cm.


What are the requirements of the fire training tower

Product description of fire training tower:

1. Multifunctional fire training tower, mainly composed of (1) simulated windows, (2) floor partitions, (3) rear frame, (4) lookout, command platform frame and main steel structure frame. There are eight simulation windows at the front end of the tower body (several floors and several windows can be customized according to needs), and floor partitions (steel plates) are arranged between the upper and lower adjacent simulation windows.


2. A rear frame corresponding to the simulation window is provided below the rear of the tower.


3. The simulation window and the floor partition, the rear frame and the main frame are connected by bolts as a whole.


4. There are safety stairs connection between floors.


5. The upper part of the tower is equipped with a lookout and command platform.


6. Anemometer, cold water belt rack and alarm can be installed as needed.


7. According to needs, a simulated fire training well can be made next to the fire training tower.


8. The fire training tower equipment is also equipped with special fire-fighting pulleys, sliding poles, simulation walls and other auxiliary facilities. The training tower has scientific structure, safe operation, convenient use, anti-corrosion treatment, hot-dip galvanizing or thermal spraying treatment, no maintenance for 50 years, safe and reliable. It has multiple functions such as fire training, lookout, wind measurement, and alarm. At the same time, it is convenient for the commander to grasp the action essentials of fire officers and soldiers at any time. It is the necessary equipment for fire fighting training exercises of armed police fire officers and soldiers. At the same time, it replaces the past history of brick-concrete fire-fighting buildings.

The above is an introduction to the requirements of the fire training tower. I hope it will be helpful to you.